Horizontal Vertical Flammability Tester HV04
Horizontal &Vertical Flammability Tester is used to determine the resistance of inner material of planes to fire according to the vertical and horizontal flammability test in Part I in Appendix F to FAR 25.
Horizontal Vertical Flammability Tester HV04
Horizontal vertical Flammability Tester is developed base on CCAR25-A. It is applied to measure the fire resistance of aircraft material.
Follows are features of flammability test machine :
- Auto electric ignition with randomly settable igniting time of 0~99.99;
- Imported needle valve to precisely control the gas flow and adjust the flame height to be 38mm;
- Flame temperature is verified to be approximate 843oC in factory and a device (optional) can be equipped to measure it;
- Imported pressure gauge and pressure regulating valve to adjust the gas pressure;
- Bensen burner as igniter with its inner diameter of 9.5mm;
- Auto recording and saving of datum of up to 6 test specimens;
For more information,you can also visit www.fyichina.com.cn
Standards
Horizontal &Vertical Flammability Tester Standard
CCAR-25 Appendix F | FAR-25 Appendix F Part I |
---|
Key specification
Key specification of Horizontal &Vertical Flammability Tester
Burner type | Bensen burner |
---|---|
I.D. of burner | 9.5mm |
Flame height | Manually adjustable, standard: 38mm |
Flame center temperature | ≥843oC(1550oF), verified in factory |
Distance between lower edge of specimen and top edge of burner |
19mm |
Igniting time | 0~99.99s, randomly settable 12s and 60s for vertical test 15s for horizontal test |
Inner size of test chamber | 305×305×610mm(L×W×H) |
Gas required | Methane, propane, butane, petrol liquefied gas or other combustible gas |
Power supply | AC220V 50Hz |
1 review for Horizontal Vertical Flammability Tester HV04