Horizontal Flammability Tester YG815B
Flammability Tester, also named Horizontal flammability tester, which is used to determine the comparative burn rates and burn resistance of textiles. In regular testing conditions, ignite the fabric sample which place in horizontal for 15 seconds. Measure the burning distance and time.
Flammability Tester YG815B
Flammability Tester (Horizontal method) is suitable for the determination
of flame retardant properties of flame retardant machine fabric, knitted fabric, coating products and laminated products. It is used to determine the tendency of textile afterburning, smoldering and carbonization.
FYI are best Flammability Tester manufacturer and Flammability Tester suppliers.
Follows are horizontal flammability tester specification :
- Data acquisition and processing by computer
- Stainless steel, resistant to heat and smoke and convenient to clean;
- Precise flowmeter to adjust flame height;
- Heat-resistant glass observation window in the front of test chamber, convenient for the user to operate;
- Metal buttons, beautiful, elegant and not easy to break.
Application
Application of horizontal flammability tester
Horizontal Flammability Tester is used for the determination method of horizontal combustion performance of various textile fabrics and also used to evaluate the flammability performance of textiles by determining the flame spreading speed in the horizontal direction.
Noted :Dimension of specimen is 350mm×100mm, take the specimen holder out from working chamber, put the specimen in specimen holder and make use face downward;
If you need more information about Horizontal Flammability Tester please contact with us.
Standards
Horizontal Flammability Tester Standard
FZ/T01028 | ASTM D5132 |
---|
Some standards might not be the full version; to read the full version for free, write an email to [email protected].
Please contact the administrator to get any violations removed.
Key specification
Key specification of Horizontal Flammability Tester
Time range | 0~99999.9s |
---|---|
Time resolution | 0.1s |
Igniting time | standard: 15s, settable |
Inner diameter of burner head | Φ9.5mm |
Distance from burner top to specimen center) | 19mm |
Power supply | AC220V 50Hz |
Dimensions | 350×350×570mm(L×W×H) |
Weight | 20kg |