Rotorless Rheometer DW5320
Rotorless Rheometer, also named Rotorless Rubber Rheometer. It is used to determine the whole vulcanization characteristics of the glue material. The test temperature is the same as the vulcanization temperature of the rubber. The vulcanizer gets a complete cure curve. On this curve, you can see the positive vulcanization point, which is the time of positive vulcanization. The maximum torque is related to hardness and tensile strength.
Rotorless Rheometer DW5320 Description
DW5320 Rotorless Curemeter, also known as moving die rheometer (MDR), is applicable for vulcanization of rubbers to acquire characteristic curves and parameters through measuring the torque which rubber materials effect on the oscillating die.
Rotorless Rheometer complies with ASTMD5289, ISO 6502-1 , GB/T 16584 international and retailer standards.
Follows are features of Rotorless Rheometer
- High accuracy sensor;
- The computer software and integrated circuit module are adopted for data acquisition, storage, processing, printing test results and curve processing;
- Adopt famous brand servo system and amplitude regulator;
- Adopt intelligent temperature measurement multi-channel extension module, adjust PID control parameters in real time;
- Die core adopts Cr6wv material with high strength and wear resistance;
- LED light source, open die automatically turn on the light, close die automatically turn off the light;
- Safety protection shield.
Application
Application of Rotorless Rheometer
Rotorless Rheometer is applicable for vulcanization of rubbers to acquire characteristic curves and parameters through measuring the torque which rubber materials effect on the oscillating die.
Rubber Testing Equipment is used to analyze the performance of rubber, Rheometer is used to develop new products and control the rubber product quality , The curves and characteristic parameters on vulcanization of rubber materials can be obtained using Rheometer based on the measurement of the torque created by the rubber material on the Oscillating die.
If you need more information about Rotorless Rheometer Testing Machine. Please contact with us.
Standards
Standards of Rotorless Rheometer
ASTM D5289 | ISO 6502-1 | GB/T 16584 |
---|
Some standards might not be the full version; to read the full version for free, write an email to [email protected].
Please contact the administrator to get any violations removed.
Key specification
Key specification of Rotorless Rheometer
Die cavity | Φ40mm hollow groove die cavity |
---|---|
Temperature range | RT~200℃ |
Temperature control accuracy | ≤±0.3℃ |
Temperature resolution | 0.01℃ |
Heating rate | RT-150℃<20min |
Measuring range of torque | 0~20N·m |
Torque resolution | 0.001N·m |
Frequency of die cavity | (1.7±0.1)Hz |
Amplitude | ±0.5°/±1° |
Setting range of vulcanization time | 1~300min |
Air supply | 0.4MPa |
Power supply | AC220V, 50Hz |
Power | 800W |
Dimensions | 660×580×1,300mm (L×W×H) |
Net weight | Approx. 260kg |
FAQs
FAQs
Q: Is the rheometer an ODR or an MDR?
A: MDR Rotorless rheometer.
1 review for Rotorless Rheometer DW5320
You must be logged in to post a review.
Andrea Jane –
It’s helpful. Thanks seller for recommending me this